ActionsPrevents Ice from Building up on the Outdoor Unit Base When Operating in Heating Mode for an Extended Period of Time in a Very Low Temperature, High Humidity Condition
Controlled by Outdoor Unit
Works During Defrost Operation and Energizes When Outdoor Temperature Drops below 36 Deg F
Function Lockout Individually Prohibits All Functions of Each Remote Controller
Supports Both Fahrenheit and Celsius
Controls Group Operation for up to 16 Indoor Units in a Single Group
Maximum Signal Receiving Distance is Approximately 22 Foot
Maximum Signal Receiving Angle is Approximately 45 to the Left and Right of Center
Standard P-Series Units Provide Full Capacity Down to 23 Deg F
Standard PUZ Heat Pump Outdoor Units Provide Full Cooling Capacity Down to 23 Deg F Outside Ambient
Centralized Controller
System Control Interface
Prevents Ice from Building up on the Outdoor Unit Base When Operating in Heating Mode for an Extended Period of Time in a Very Low Temperature, High Humidity Condition
Controlled by Outdoor Unit
Works During Defrost Operation and Energizes When Outdoor Temperature Drops below 36 Deg F
Microprocessor Based Electronic Temperature Control with a Built-In Non-Volatile Eprom to Retain Settings Even after a Power Outage
Remote Sensor that Can be Spliced for Sensing up to 400 Foot with 22 AWG Wire
Simple Keypad Programming of Set Point Temperature, Differential
LCD Readout of Sensor Temperature, Control Settings, Relay Status and Onboard Diagnostics
Lockout Switch to Prevent Tampering by Unauthorized Personnel
Allows for a Mitsubishi Electric Indoor Unit to Communicate with to the Kumo Cloud App and Web Service
Wireless Connection over Local Network
Connection to Indoor Unit via CN105
WPS Button to Pair with Wireless Router
Reset Button to Reset All Settings
3-LEDS to Display Device Status
RF Channel
AES Encryption
PSK Authentication
Prevents Ice from Building up on the Outdoor Unit Base When Operating in Heating Mode for an Extended Period of Time in a Very Low Temperature, High Humidity Condition
Controlled by Outdoor Unit
Works During Defrost Operation and Energizes When Outdoor Temperature Drops below 36 Deg F
Allow for a Mitsubishi Electric Indoor Unit to be Controlled Remotely or Locally with to the Kumo Cloud App
Wireless Connection Over a Local Network
Mode Button to Enter Bluetooth Configuration to Pair with Local Wireless Network
Reset Button to Reset All Setting on Wireless Interface
Front Wind Baffle Allow Outdoor Unit to Operate at Full Capacity Down to the Temperature Range Shown in the Table Above
Prevent Wind from Reversing Outdoor Fan Rotation when Unenergized
Durable and Low Maintenance Construction
Automatic Return to Preset Temperature Setpoint if Set Point is Changed from the Remote Controller after a Preset Time Range
Energy-Saving Operation Schedule
Night Setback
Main Display
Backlight Display
Filter Maintenance Notification
Error Code Notification
Front Wind Baffle Allow Outdoor Unit to Operate at Full Capacity Down to the Temperature Range Shown in the Table Above
Prevent Wind from Reversing Outdoor Fan Rotation when Unenergized
Durable and Low Maintenance Construction
Field Capability to Set Up Points and Troubleshooting Codes on the VFD Controller
Standard P-Series Units Provide Full Capacity Down to 23 Deg F
Standard PUZ Heat Pump Outdoor Units Provide Full Cooling Capacity Down to 23 Deg F Outside Ambient